Heat pump not heating — normal behavior vs. a real problem

Many heat pump "not heating" calls turn out to be normal operation: heat pumps deliver a larger volume of warmer-but-not-hot air than a furnace, and in cold, damp weather they pause heating for a few minutes at a time to defrost the outdoor coil. A real problem looks different: the outdoor coil stays encased in ice, the system blows cool air continuously, the house only warms when auxiliary heat runs, or the outdoor unit isn't running at all. Check the thermostat mode, the filter, the breakers, and the outdoor unit's clearance first; a stuck defrost, reversing valve fault, or refrigerant leak needs a technician.

Reviewed by Vasiliy BardadinOwner & Lead Technician, Statewide HVAC · CSLB #1023360

On this page · 5 sections
  1. 01First, decide whether it's actually broken
  2. 02Defrost: the normal cycle that looks like a breakdown
  3. 03Safe checks a homeowner can make
  4. 04Auxiliary and emergency heat, and why the bill jumps
  5. 05Problems that need a technician

First, decide whether it's actually broken

A heat pump heats differently from a gas furnace, and that difference is behind a lot of worried calls. Lennox's homeowner guide puts it plainly: heat pumps satisfy heating demand by delivering large amounts of warm air, while furnaces deliver lower volumes of considerably hotter air. Put your hand over a register and heat-pump air can feel lukewarm, especially compared with the furnace you grew up with, even while the house is warming normally.

So the better test is the thermostat, not your hand. If the indoor temperature holds at the setpoint or climbs slowly toward it, the system is doing its job. If the house keeps losing ground over an hour or more while the system runs, or the air from the registers is cooler than the room, something needs attention.

Homeowners who move from a furnace to a heat pump sometimes also notice longer run times. A modern variable-speed heat pump is designed to run long, gentle cycles rather than short blasts, so continuous operation on a cold morning isn't a fault by itself.

Defrost: the normal cycle that looks like a breakdown

In heating mode the outdoor coil runs colder than the outside air, so moisture freezes on it. Lennox's user guide says frost develops on the outdoor coil when outdoor temperatures are below 45°F, and an electronic control runs a defrost cycle lasting 5 to 15 minutes at preset intervals to clear it. Rheem's manual describes the same thing: during defrost the outdoor fan stops while the compressor keeps running to warm the coil, and some steam may rise from the outdoor unit as melted frost evaporates.

That's why defrost is so often mistaken for a failure: the outdoor fan goes quiet, a cloud of vapor comes off the unit, there's a whoosh as the system shifts, and the air indoors can briefly feel cool. Lennox notes the thermostat may bring on auxiliary heat during defrost to cover the gap, and the system returns to normal heating when the cycle ends.

In the Sacramento Valley this tends to show up on foggy or frosty winter mornings, when the air is cold and saturated and frost builds quickly. Foothill homes in Placer, El Dorado and Nevada counties see colder nights and more frequent defrost. Frequent defrost on those mornings is expected; a coil that never clears is not.

Normal defrost vs. a defrost or icing problem
What you seeUsually normalCall a technician
Frost on the outdoor coilThin, even frost that clears every so oftenThick ice that covers the coil and never melts off
Steam from the outdoor unitA short burst of vapor while the fan is stoppedConstant steam, or none ever on obviously frosted days
Outdoor fan stoppedFor a few minutes, then it restartsStopped for long periods while the compressor runs or hums
Cool air indoorsBriefly, during a defrost cycleContinuously, with the system calling for heat
Ice building in one spotRarely normalIce that keeps growing in one area, often a drainage, airflow or charge issue

Safe checks a homeowner can make

Manufacturers' own pre-service checklists cover most of what a homeowner should try. Lennox's list is short: confirm the thermostat settings, confirm electrical disconnects are on, check for blown fuses or tripped breakers, make sure the access panels are in place, and verify the air filter is clean. Before you touch anything at the outdoor unit, switch its power off at the disconnect.

  • Thermostat mode: set to HEAT (not COOL, OFF, or a fan-only setting) with the setpoint a few degrees above room temperature. If the fan is set to ON instead of AUTO, the blower will move unheated air between cycles and during defrost, which feels like the system blowing cold.
  • Batteries and display: a blank or flickering thermostat display can mean dead batteries or a wiring/power fault.
  • Breakers: a heat pump usually has separate breakers for the outdoor unit and the indoor air handler (and sometimes for the backup heat strips). One tripped breaker can leave the fan running with no heat. If a breaker trips again after one reset, leave it off and call for service.
  • Filter: a clogged filter cuts airflow across the indoor coil, which reduces heat delivery and can trip safety limits. Replace it with the same type and size.
  • Registers and returns: make sure furniture, rugs and curtains aren't blocking them, and avoid closing many supply vents to "push" heat elsewhere.
  • Outdoor unit: clear leaves, grass clippings, and anything stored against it. Lennox recommends trimming shrubbery back and keeping snow below the louvered panels in areas that get it.
  • After a long power outage: Lennox advises that if power to the unit has been off for several hours or more, you run on EMERGENCY HEAT and allow a six-hour compressor crankcase warm-up before switching back to normal HEAT. Check your own model's manual for its instructions.

Auxiliary and emergency heat, and why the bill jumps

Most ducted heat pumps have a backup heat source, typically electric resistance strips in the air handler, sometimes a gas furnace in a dual-fuel setup. Auxiliary (AUX) heat is the backup the system brings on automatically: during defrost, when the heat pump can't keep up on a cold night, or when a large setpoint increase calls for fast recovery. Emergency heat (EM HT) is a manual thermostat setting that locks the heat pump out and runs on backup alone.

Rheem's manual describes emergency heat as a backup mode to be used only if there is a suspected problem with the outdoor unit, and warns that sustained use of electric resistance heat in place of the heat pump will increase electric utility costs. That's the important point: if your house only stays warm when AUX is on, or someone left the thermostat on EM HEAT, the house can feel fine while the heat pump itself is broken or idle, and the electric bill shows it.

Deep overnight setbacks can have a similar effect. ENERGY STAR's guidance for heat pumps is to pick a comfortable temperature and leave it, because unlike furnaces, heat pumps don't save energy by being turned down while you're away or asleep. A big morning recovery is a common reason the AUX light comes on.

If AUX or EM heat is lit on mild afternoons, or the system seems to be running on backup more than it used to, that's a reason to have the heat pump side checked rather than just living with it.

Problems that need a technician

Once the simple items are ruled out, the remaining causes involve refrigerant, high-voltage components or controls, and they need diagnostic tools and an EPA-certified technician:

  • Stuck defrost or failed defrost controls: if a defrost sensor or control board fails, the coil can stay iced (no defrost) or the unit can get stuck defrosting and blow cool air. Don't chip or pry ice off the coil; the fins and tubing are easily damaged.
  • Reversing valve: this valve switches the refrigerant flow between cooling and heating. If it sticks, or its solenoid or control signal fails, the system may cool when it should heat or sit somewhere in between. Diagnosis means checking the thermostat signal, the solenoid coil, and refrigerant pressures and temperatures.
  • Low refrigerant: refrigerant circulates in a sealed loop, so low charge always means a leak. Symptoms include weak heat that gets worse over weeks, unusual icing, and long run times. Adding refrigerant without finding the leak is a temporary fix. Our refrigerant leak guide covers the repair-or-replace decision.
  • Outdoor fan motor or capacitor: if the outdoor fan doesn't run while the compressor does (outside of defrost), the coil can't pick up heat and ices heavily.
  • Compressor not running: if the outdoor fan runs but the system delivers no heat and the unit isn't defrosting, the compressor or its start components may have failed, which needs electrical testing.
  • Undersized or aging equipment: if a system that once kept up now struggles every cold snap, especially in foothill homes, capacity at low temperatures may not match the house. Our HSPF2 and cold-weather guide explains how to read that.

Common questions

Why is my heat pump blowing cold air for a few minutes?

Most often it's a defrost cycle. The system briefly reverses to warm the outdoor coil, the outdoor fan stops, steam may rise off the unit, and the indoor air can feel cool until it switches back. Manufacturers such as Lennox describe defrost cycles of roughly 5 to 15 minutes; if cool air continues well beyond that, have it checked.

Is steam coming from my outdoor unit a sign of a fire or a leak?

No. Steam during defrost is normal: the warm coil melts frost and some of it evaporates. Smoke with a burning smell is different. If you smell burning, turn the system off at the thermostat and the breaker and call for service.

Should I switch to emergency heat if my heat pump stops heating?

Emergency heat is meant as a temporary backup when the outdoor unit has a problem, and it can keep the house warm until a technician arrives. It runs on backup heat alone, usually electric resistance, which costs more to operate than the heat pump. Use it short-term and get the heat pump repaired rather than leaving it on.

My heat pump air feels lukewarm. Is it broken?

Not necessarily. Heat pumps move a lot of warm air rather than a smaller amount of very hot air, so register air often feels cooler than furnace air. If the house reaches and holds the thermostat setting, it's working. If the house keeps falling behind or the air is cooler than the room, schedule a diagnosis.

My outdoor unit is covered in ice. What should I do?

Light frost that clears periodically is normal. A coil that is solidly iced and never clears points to a defrost, airflow, fan, or refrigerant problem. Don't chip at the ice; turn the system to emergency heat or off and call for service.

Sources

Program amounts and rules change. Confirm current terms with the source before you rely on them.

Reviewed and published by Statewide HVAC

Vasiliy Bardadin, owner and lead technician of Statewide HVAC, standing outdoors in a white Statewide HVAC polo.

Vasiliy Bardadin

Owner & Lead Technician

Statewide HVAC is owner-operated and Roseville-based.

Statewide HVAC is a CSLB-licensed heating and air conditioning contractor (#1023360) serving the Sacramento region from Roseville. Our guides are written for local homeowners, list their sources, and show the date they were last reviewed. About us

Questions this guide didn't cover?

We'll answer them on your project — no sales pressure.

(916) 461-3405Request Service