Gas supply, burners, and ignition
ENERGY STAR's heating checklist starts with gas connections, gas pressure, and burner combustion, and notes that improperly operating gas connections are a fire hazard. The technician checks the appliance connector and shutoff for leaks, verifies manifold gas pressure against the furnace rating plate, and watches the burner flame for shape and color.
A furnace that's been idle since spring often has dust on the burners and an oxidized flame sensor. The flame sensor is a thin metal rod that proves flame is present; when it coats over, the furnace lights, then shuts down seconds later. Cleaning it and checking its signal is one of the most common fall fixes. The hot-surface igniter is inspected for cracks and checked electrically.
The heat exchanger inspection
The heat exchanger separates combustion gases from the air your blower sends through the house. ENERGY STAR notes that a dirty burner or cracked heat exchanger causes improper burner operation. A technician inspects visible surfaces for cracks, holes, corrosion, soot, and heat discoloration, and watches the flame for disturbance when the blower starts — a classic sign of a breach.
If a crack is confirmed, the furnace should be shut down. Our cracked heat exchanger article explains why that failure is a replacement rather than a repair.
Venting and draft
Combustion products have to leave the house reliably. On an 80% AFUE furnace that means a metal B-vent flue with proper draft; on a 90%+ condensing furnace it means sealed PVC vent and intake piping plus a condensate drain and trap. The tune-up confirms the vent is intact, properly sloped and supported, and unobstructed, and that the draft inducer and pressure switch prove venting before the burners light.
Condensing furnaces add a drain path that can clog with sediment; a blocked condensate trap is a common cause of lockouts on high-efficiency models.
Safety controls and the heat cycle
Every gas furnace has safety switches that shut the burners off if something goes wrong. Each one gets tested, not just assumed:
- High-limit switch — shuts burners off if the heat exchanger overheats, usually from restricted airflow
- Flame rollout switches — trip if flame escapes the burner area
- Pressure switch — confirms the inducer has established draft before ignition
- Blower door switch — prevents operation with the panel off
- Full heat cycle observed — ignition, flame proving, blower delay, steady-state, and shutdown
Blower, airflow, and filter
ENERGY STAR calls for cleaning and adjusting blower components and lubricating moving parts where applicable. A dirty blower wheel moves less air, which raises heat exchanger temperature and can trip the high limit. The filter gets checked and changed — heating season brings dry, dusty indoor air and the filter sees both seasons' load.
Carbon monoxide alarms — the California requirement
California Health and Safety Code §17926 requires owners of dwelling units with a fossil-fuel-burning heater or appliance, a fireplace, or an attached garage to install carbon monoxide devices approved and listed by the State Fire Marshal. For existing single-family homes, the requirement took effect July 1, 2011.
A furnace tune-up is a good moment to check that alarms are present and within their service life — most alarms print a replacement date or service life on the unit. A CO alarm is a backstop; it doesn't replace an inspected combustion system, and an inspected combustion system doesn't replace the alarm.
Common questions
Why does my furnace light and then shut off after a few seconds?
The most common cause is a dirty or oxidized flame sensor that can't prove flame, so the control board shuts the gas off for safety. It's especially common on the first cold mornings after the furnace sat idle all summer. Other causes include a venting or pressure-switch problem, which is why it's worth a diagnosis rather than repeated resets.
Is the burning smell on first startup normal?
A brief dusty smell the first time the furnace runs in fall is common — dust burning off the heat exchanger and burners. A smell that persists, or that resembles gas or sulfur, is not normal: turn the system off and call for service, and if you smell gas, leave the house and call the gas utility from outside.
Does a CO alarm make a furnace inspection unnecessary?
No. The alarm warns you after carbon monoxide is already in the living space. The inspection is how you find a cracked heat exchanger, a blocked flue, or a failed safety switch before it produces that condition. California law requires the alarm; good practice adds the inspection.
Do high-efficiency furnaces need different maintenance?
They add items: the PVC vent and intake terminations need to be clear, and the condensate trap and drain need to be clean and flowing. A clogged condensate trap is one of the most frequent causes of lockouts on 90%+ furnaces.