What carbon monoxide is and why furnaces produce it
Carbon monoxide (CO) is a gas you cannot see, smell, or taste. The CPSC calls it "a deadly, colorless, odorless, poisonous gas." It forms whenever a carbon-based fuel like natural gas or propane burns without enough oxygen to complete the combustion reaction. Every gas furnace produces some CO during normal operation. The venting system is designed to carry those combustion gases safely outside before they ever reach your living space.
Problems start when either the combustion process goes wrong (producing more CO than normal) or the venting fails (letting normal exhaust leak indoors). A furnace with a cracked heat exchanger, a blocked flue, a disconnected vent connector, or backdrafting from negative house pressure can all push CO into the air you breathe. For a deeper look at what a cracked exchanger means, see our heat exchanger guide.
How CO enters the living space
A standard-efficiency furnace (80 AFUE) uses a metal flue that relies on hot exhaust rising through a B-vent or chimney. A high-efficiency condensing furnace (90 AFUE and above) uses sealed PVC intake and exhaust pipes that vent through an exterior wall or roof. Each venting style has its own failure modes.
| Venting type | What can go wrong | What you might notice | Who handles it |
|---|---|---|---|
| B-vent / chimney (80% furnace) | Disconnected vent connector, blocked chimney, negative house pressure causing backdraft | Exhaust smell near the furnace, moisture on walls or windows near the unit, CO alarm activation | Technician inspects the vent run, connections, and draft |
| PVC sealed vent (90%+ furnace) | Blocked intake or exhaust pipe (leaves, ice, bird nests), separated pipe joint | Furnace locks out with a pressure-switch error code, visible blockage at the outdoor termination | Homeowner can clear visible obstructions at the outdoor termination; a tech handles internal joints and the pressure switch |
| Cracked heat exchanger (any furnace) | Combustion gases leak into the supply air stream through cracks or separations in the exchanger | CO alarm sounds while the furnace runs, soot near burners (tech observation), occupant symptoms | Technician; the furnace should not run until the exchanger is inspected |
| Improper combustion (any gas furnace) | Dirty burners, wrong gas pressure, insufficient combustion air | Yellow or flickering burner flame visible through the sight window, soot buildup | Technician; adjusting gas pressure or cleaning burners is not a homeowner task |
Where CO alarms belong
The CPSC recommends battery-operated or battery-backup CO alarms on every level of the home and outside each sleeping area. Interconnected alarms are best: when one sounds, they all sound. The CPSC also notes that CO alarms should not be installed in attics or basements unless those spaces include a sleeping area.
Place alarms at roughly breathing height on a wall or on the ceiling, following the specific manufacturer's mounting instructions. Keep them away from kitchens and heating vents, which can cause nuisance trips. The CPSC notes that the test button verifies the alarm's circuitry is working but does not test the sensor's accuracy, so monthly testing is a minimum, not a full verification. Replace batteries at least once a year. Replace the alarm itself on the schedule printed in the manufacturer's literature, typically every five to seven years.
If your furnace sits in a garage, attic, or closet, an alarm near the access point to that space gives early warning before CO can spread through the house. California law already requires CO alarms in homes with gas appliances or an attached garage.
Symptoms of CO exposure
The CDC lists the most common symptoms of CO poisoning as headache, dizziness, weakness, upset stomach, vomiting, chest pain, and confusion. These symptoms are often described as flu-like, which makes CO exposure easy to misidentify, especially in winter when actual flu is circulating. The CPSC adds that high-level exposure can cause mental confusion, loss of muscular coordination, loss of consciousness, and death.
People who are asleep or who have been drinking are at higher risk because they may not recognize symptoms before losing consciousness. The CDC notes that infants, the elderly, and people with chronic heart disease, anemia, or breathing problems are more vulnerable.
A pattern worth watching: if symptoms appear when the furnace runs and ease when you leave the house, CO should be high on the suspect list. Do not wait for certainty. Get everyone outside and call 911.
What to do if a CO alarm sounds
This is not a drill situation. The CPSC says to get outside to fresh air immediately and call 911 from a safe location. Account for everyone in the household. Do not go back inside until emergency responders say it is safe.
Do not restart the furnace. Do not try to find the source of the leak yourself. A fire department or utility crew will measure CO levels inside the home with instruments far more sensitive than a residential alarm. If the source is the furnace, it stays off until a licensed technician inspects the heat exchanger, the venting, and the combustion system. If you need furnace repair after a CO event, the technician should perform a combustion analysis before clearing the unit to run.
Preventing CO problems: the annual inspection
The CPSC recommends a yearly professional inspection of all fuel-burning home heating systems. That inspection should cover the furnace, its burners, the heat exchanger, all vent connections, the flue or PVC vent run, the draft or pressure switch operation, and the condensate system on high-efficiency units. Our tune-up checklist walks through what a thorough maintenance visit covers.
Between inspections, you can do a few things that reduce risk without opening the burner compartment:
- Replace the filter on the manufacturer's schedule. A clogged filter starves airflow and can cause the furnace to overheat, which stresses the heat exchanger.
- Check the outdoor PVC vent terminations on a 90%+ furnace. Clear leaves, debris, or ice. Our condensing furnace venting guide explains what to look for.
- Keep supply registers and return grilles open and unblocked throughout the house.
- Make sure the furnace blower door is fully seated. On most furnaces the unit will not run without it, but a partially open door can affect combustion air.
- Never seal up all the fresh-air pathways in the house without considering combustion air. A natural-draft furnace draws its combustion air from the room around it; a tight house can create negative pressure that backdrafts the flue.
Sacramento-region considerations
Mild valley winters mean many local furnaces run only a few months. A furnace that sat idle from April through October can develop rust on the heat exchanger or collect debris in vent pipes. The first-of-season startup is a good time to check your CO alarms and walk the outdoor vent terminations. See our first start of winter guide for a step-by-step list.
Foothill homes at elevation often use propane, and some run the furnace heavily from November through March. Propane furnaces carry the same CO risks as natural-gas units. Snow and ice at the vent terminations are more common at higher elevations, and a blocked vent can trigger a pressure-switch lockout or, on an older unit without sealed combustion, push exhaust back into the house.
In the valley, many furnaces are installed in garages, attics, or interior closets. Each location has its own implications for CO safety and detection. A licensed HVAC contractor can evaluate whether the venting in your home meets current code.
The gas-smell scenario versus the CO scenario
Natural gas and CO are different hazards and call for different responses. Natural gas has a sulfur or rotten-egg smell added by the utility (mercaptan) so you can detect a leak. CO has no odor at all.
If you smell gas: leave the house immediately. Do not flip light switches, use a phone inside, or do anything that could create a spark. Call your gas utility or 911 from outside. PG&E operates a 24-hour gas-leak line for the Sacramento region.
If a CO alarm sounds or people have CO symptoms: get everyone outside and call 911 from outside. The furnace should not be restarted until it has been inspected by a qualified technician.
Common questions
Can a furnace produce carbon monoxide?
Yes. Every gas or propane furnace produces CO as a byproduct of combustion. Under normal conditions the venting system carries those gases outside. Problems like a cracked heat exchanger, a blocked vent, or backdrafting can let CO enter the living space.
Where should I put CO alarms if my furnace is in the attic?
Install a CO alarm outside each sleeping area and on every level of the home. If the furnace is in the attic, adding an alarm near the attic access point provides early warning. The CPSC says an alarm in the attic itself is not necessary unless someone sleeps there.
What are the symptoms of carbon monoxide exposure?
The CDC lists headache, dizziness, weakness, upset stomach, vomiting, chest pain, and confusion as the most common symptoms. They resemble the flu, which is why CO exposure is easy to miss in winter. If symptoms appear when the furnace is running and ease when you leave the house, get outside and call 911.
How often should a CO alarm be replaced?
Follow the replacement schedule in the manufacturer's literature. Most residential CO alarms have a sensor life of five to seven years. Test the alarm monthly and replace the batteries at least once a year.
Does a high-efficiency furnace eliminate CO risk?
No, but it reduces certain risks. A 90%+ condensing furnace uses sealed PVC venting that does not rely on the house for combustion air, which eliminates backdrafting. It can still produce CO if the heat exchanger cracks or a vent pipe separates. CO alarms are still necessary.
What should I do if my CO alarm goes off?
Get everyone outside to fresh air immediately and call 911 from a safe location. Do not go back inside until emergency responders clear the home. Do not restart the furnace until a licensed technician has inspected it.
Can a blocked vent pipe cause carbon monoxide inside the house?
Yes. On a standard-efficiency furnace, a blocked chimney or disconnected vent connector can force exhaust back into the room. On a high-efficiency furnace, a blocked PVC exhaust pipe usually triggers a pressure-switch lockout before CO reaches dangerous levels, but a partially blocked pipe or a separated joint may not trip the switch.
Sources
- U.S. Consumer Product Safety Commission — Carbon Monoxide Questions and Answers (checked November 10, 2026)
- U.S. Consumer Product Safety Commission — CO Alarms (checked November 10, 2026)
- Centers for Disease Control and Prevention — Carbon Monoxide (CO) Poisoning Basics (checked November 10, 2026)
- U.S. Consumer Product Safety Commission — Home Heating Equipment — Carbon Monoxide Information Center (checked November 10, 2026)
- U.S. Department of Energy — HVAC Direct Vent Equipment (checked November 10, 2026)
Program amounts and rules change. Confirm current terms with the source before you rely on them.
Reviewed and published by Statewide HVAC

Vasiliy Bardadin
Owner & Lead Technician
Statewide HVAC is owner-operated and Roseville-based.
Statewide HVAC is a CSLB-licensed heating and air conditioning contractor (#1023360) serving the Sacramento region from Roseville. Our guides are written for local homeowners, list their sources, and show the date they were last reviewed. About us