What the ignition sequence looks like
A modern gas furnace follows a strict sequence every time the thermostat calls for heat. The control board starts the draft inducer motor, waits for the pressure switch to confirm airflow, then powers the ignitor. On a hot-surface ignition system the ignitor glows orange for about 30 seconds before the gas valve opens. On a spark ignition system you hear rapid clicking instead. Once gas flows and the burners light, a flame sensor confirms the flame within a few seconds. If the flame sensor does not detect a flame, the control board closes the gas valve and tries again.
Most boards allow three to four ignition attempts before locking out. After a lockout, the furnace will not try again until you cycle power or until a timed lockout period expires. The LED on the control board will flash a fault code that points to the stage where the sequence failed. Our error codes guide explains how to read and interpret those flash patterns.
Hot-surface ignitor failure
The hot-surface ignitor is the most common single-point failure in modern furnaces. Carrier notes that these ignitors are made of silicon carbide or silicon nitride and operate at extreme temperatures, so they degrade over time. Cracking, carbon deposits, or an open circuit in the element all prevent it from reaching ignition temperature.
From outside the furnace, the clue is straightforward: the inducer starts, but you do not see any glow through the sight window, and the burners never light. The control board typically posts an ignitor-failure or no-flame code. Replacing the ignitor is a common repair, but it requires opening the burner compartment and working near gas and line voltage, so it is technician work.
Carrier also notes that touching an ignitor element with bare hands during installation can leave oils that create hot spots and cause premature cracking. This is a useful detail if you have had a recent repair and the ignitor failed again quickly.
Spark ignition failure
Some furnaces use a high-voltage spark rather than a glowing element. You hear rapid clicking during the ignition attempt. If the clicking happens but the burners do not light, the spark module may be weak, the electrode gap may be wrong, or gas is not reaching the burners. A spark system that clicks endlessly without igniting will also lock out after several attempts.
Intermittent pilot systems are a variation. A spark lights a small pilot flame, and that pilot lights the main burners. If the pilot lights but the main burners do not fire, the problem may be in the main gas valve or the pilot assembly rather than the spark module.
Flame sensor problems
The flame sensor is a thin metallic rod mounted in the burner area. It uses a principle called flame rectification: a tiny electrical current passes through the flame, and the control board reads that current to confirm combustion. Carrier describes the normal reading as a few microamps. When carbon buildup or oxidation insulates the rod, the current drops below the board's threshold and the board shuts the gas valve even though a flame is present.
The telltale pattern is burners that light, burn for two to five seconds, and then go out. The furnace retries, fails again, and eventually locks out. This is one of the most common service calls, because it looks alarming but is usually a quick fix: the technician removes the sensor, cleans the rod, and reinstalls it. If the sensor is cracked or the ceramic insulator is damaged, it gets replaced.
Flame sensor cleaning involves removing a component from the burner compartment. It is not a homeowner task. A safety switch should never be bypassed to keep the furnace running when the flame sensor is not reading correctly.
Other causes of no ignition
Ignitor and flame sensor failures account for most no-ignition calls, but a few other parts can produce the same symptom:
- Gas valve: If the ignitor glows but gas never flows, the gas valve solenoid may have failed. The board posts a no-flame code because the flame sensor never sees fire.
- Pressure switch: A pressure switch that will not close prevents the board from powering the ignitor at all. Common reasons are a failed switch, a cracked inducer hose, or blocked vent piping.
- Blocked vent or intake (90%+ condensing furnaces): Leaves, nests, ice, or snow at the outdoor PVC terminations can prevent the pressure switch from closing. You can check this yourself by inspecting where the pipes exit the house.
- Gas shutoff valve: The manual shutoff handle on the gas pipe near the furnace must be parallel to the pipe. Perpendicular means closed.
- Control board: A dead or damaged board may power the inducer but never advance to the ignition step. Error codes, if any, help narrow this down.
What you can safely check
These checks do not involve opening the burner compartment or touching gas or electrical parts:
| Check | What to look for | What to do |
|---|---|---|
| Thermostat | Set to Heat, target above current temp, batteries fresh | Correct settings; replace batteries if needed |
| Power switch and breaker | Switch on, breaker not tripped | Flip switch on; reset breaker once |
| Filter | Gray, clogged, no light visible through media | Replace with same size |
| Gas shutoff valve | Handle perpendicular to pipe means closed | Turn handle parallel to pipe to open |
| Outdoor PVC vent pipes (condensing furnace) | Leaves, nests, ice, or debris at termination | Clear the obstruction carefully |
| LED error code | Count blinks through the sight window on the blower door | Match to chart on inside of door panel; report code to technician |
| Sight window observation | Inducer running? Ignitor glowing? Flame appears then disappears? | This narrows the problem. Report what you see |
Lockouts and when to stop resetting
A lockout is the control board's way of protecting the furnace and your home after repeated ignition failures. One power-cycle reset is reasonable. If the furnace locks out again on the next attempt, the failure is consistent and resetting it again will not help.
Write down the error code and call for furnace repair. Repeated forced restarts on a furnace that cannot prove flame means unburned gas is entering the heat exchanger and combustion chamber on every failed try. The safety controls are doing their job.
Staying safe while troubleshooting
If you smell gas at any point, stop immediately, leave the house without flipping switches, and call your gas utility or 911 from outside. Do not try to find the leak.
The EPA recommends having fuel-burning appliances inspected by a trained professional at the beginning of every heating season. Annual maintenance catches ignitor wear, flame-sensor buildup, and venting issues before they leave you without heat. For a broader look at keeping your heating system running, visit our heating hub.
The U.S. Consumer Product Safety Commission recommends CO alarms on every level of the home and outside sleeping areas, ideally interconnected. If a CO alarm goes off while your furnace is attempting to run, get everyone outside into fresh air and call 911.
Common questions
Why does my furnace click but not light?
Clicking is the spark ignition system trying to light the burners. If it clicks repeatedly without igniting, the spark electrode may be worn, the gas valve may not be opening, or there is a gas supply issue. Let the furnace lock out, note the error code, and call for service.
What does it mean when the ignitor glows but the burners do not light?
The ignitor is working, but gas is not reaching the burners. The most common causes are a failed gas valve solenoid, a closed manual gas shutoff, or a gas supply interruption to the house.
How can I tell if it is the flame sensor?
The classic sign is burners that light and then go out within a few seconds, followed by retries and eventually a lockout. The error code on the control board will usually reference flame sense failure or low flame signal. A technician cleans or replaces the sensor.
Can I clean the flame sensor myself?
The flame sensor is mounted inside the burner compartment. Accessing it means removing a panel and working near gas and electrical connections. This is technician work. A safety component like the flame sensor should never be bypassed.
How often do ignitors fail?
There is no fixed schedule. Hot-surface ignitors are wear items that degrade with every heating cycle. Some last the life of the furnace; others fail after several years. Annual maintenance lets a technician check the ignitor's condition before it fails on a cold night.
Why does my furnace lock out after three tries?
The control board limits ignition attempts to prevent unburned gas from accumulating. Three or four failed attempts trigger a lockout that requires a power cycle or a timed wait. If it locks out again after resetting, the failure is real and needs professional diagnosis.
Does a furnace that will not ignite pose a carbon monoxide risk?
A furnace that never lights does not produce CO, but one that lights briefly and burns poorly could. If your CO alarm sounds or anyone in the house feels headache, dizziness, or nausea while the furnace is cycling, get everyone outside and call 911.
Sources
- Carrier — What is a Furnace Ignitor? (checked November 10, 2026)
- Carrier — Furnace Flame Sensor: What It Is and How to Fix It (checked November 10, 2026)
- Trane — Furnace Not Igniting? Find Out Why and What to Do (checked November 10, 2026)
- U.S. Consumer Product Safety Commission — Home Heating Equipment — Carbon Monoxide Information Center (checked November 10, 2026)
- U.S. Environmental Protection Agency — Carbon Monoxide's Impact on Indoor Air Quality (checked November 10, 2026)
Program amounts and rules change. Confirm current terms with the source before you rely on them.
Reviewed and published by Statewide HVAC

Vasiliy Bardadin
Owner & Lead Technician
Statewide HVAC is owner-operated and Roseville-based.
Statewide HVAC is a CSLB-licensed heating and air conditioning contractor (#1023360) serving the Sacramento region from Roseville. Our guides are written for local homeowners, list their sources, and show the date they were last reviewed. About us