First, confirm what 'not cooling' means
A useful first measurement is the temperature split: the difference between the air going into the return grille and the air coming out of a nearby supply vent after the system has run for 15 minutes or so. A household thermometer is enough for a rough reading.
Many technicians use a split of roughly 15-20°F as a rule-of-thumb sign of a system that's working, though the expected number varies with indoor humidity and the equipment. A split in the single digits means the system is moving air but not removing much heat. Warm air with no split at all usually means the outdoor unit isn't doing its job.
The causes, in the order to check them
Working from the simplest and most common cause to the least common saves time and money:
| Cause | What you might notice | Who fixes it |
|---|---|---|
| Thermostat setting or failure | Fan on 'On' instead of 'Auto' blows uncooled air between cycles; dead display | Homeowner first, then technician |
| Clogged filter | Weak airflow, cool-but-not-cold air, sometimes ice | Homeowner |
| Dirty outdoor (condenser) coil | Unit runs constantly, outdoor air off the top feels hotter than usual | Homeowner can rinse lightly; technician for a deep clean |
| Outdoor fan or compressor not running | Outdoor unit hums, or fan spins but no hot air comes off the top | Technician — often a capacitor or contactor |
| Low refrigerant (leak) | Gradual loss of cooling over weeks, ice on lines, hissing | Technician — leak search and repair |
| Frozen evaporator coil | Ice on the copper line at the indoor or outdoor unit, airflow drops | Turn off, thaw, then diagnose the cause |
| Duct leaks or a disconnected duct | One area much warmer than others, cool air leaking into attic | Technician |
Airflow: the cause people underestimate
An air conditioner is a heat-moving machine, and it can only move the heat that air carries to it. A clogged filter, a dirty evaporator coil, closed or blocked vents, or undersized return ducting all reduce the air crossing the indoor coil. Less air means less heat absorbed, a colder coil, and eventually ice.
Airflow problems also show up as a system that cooled fine for years and slowly got worse — the filter slot that never got changed, or a coil that collected years of fine dust. These are the cheapest problems on the list to solve, which is why they're checked first.
When the outdoor unit isn't doing its part
Stand by the outdoor unit while the system is calling for cooling. The fan on top should be spinning and the air coming off it should feel noticeably warm — that's the heat from your house being rejected outside.
If the fan isn't spinning, or the unit hums without starting, the problem is very often a failed run capacitor or a worn contactor. Both are common, relatively small repairs. If the fan runs but the air off the top is no warmer than outdoor air, the compressor may not be running, which needs electrical testing to sort out.
Low refrigerant always means a leak
Refrigerant isn't used up like fuel. It circulates in a sealed loop, so a system that is low on charge has a leak somewhere. Adding refrigerant without finding the leak restores cooling temporarily but doesn't fix the problem.
Whether to repair the leak or start planning a replacement depends on where the leak is, how old the system is, and which refrigerant it uses — covered in detail in our refrigerant leak decision guide.
Common questions
My AC cools at night but not in the afternoon. Is it broken?
Not necessarily. On the hottest afternoons a correctly sized system can run continuously and fall a few degrees behind. If it falls far behind, or the vent air isn't noticeably cool, a dirty outdoor coil, weak capacitor, or low refrigerant charge are common culprits that the heat exposes.
Can a dirty filter really stop an AC from cooling?
Yes. A badly clogged filter can restrict airflow enough that the indoor coil gets too cold and freezes, which blocks airflow further. Replacing the filter is the first thing to try — though if the coil has already frozen, it needs to thaw before cooling returns.
Should I hose off my outdoor AC unit?
A gentle rinse can help if the coil has visible dust, leaves, or cottonwood fluff on it. Turn the power off at the outdoor disconnect first, use low pressure (never a pressure washer, which bends the fins), and spray carefully. A heavily matted coil may need a technician's coil cleaner.
Why is only one room not cooling?
Single-room problems usually point to the ductwork rather than the AC itself — a crushed or disconnected duct, a closed damper, a long duct run, or a room with a heavy solar load like west-facing glass. A technician can measure airflow at the vent to find out which.